Tankless Water Heaters / Electric / Gas/ Takagi TK Jr. / Gas Water Heater Specs
Go to TanklessWaterHeatersDirect Home Page About us Go to your Personal Shopping Cart Contact Us with your questions
HACKER SAFE certified sites prevent over 99.9% of hacker crime.

Gas Tankless Water Heaters
Bosch AquaStar 2400ES
Bosch AquaStar 2700ES
Bosch AquaStar 1600H
Bosch AquaStar 125FX
Bosch AquaStar 1600P
Bosch AquaStar 125BO
Bosch AquaStar 1600PS
Bosch AquaStar 1000P
Reconditoned Heaters

Takagi T-KJr
Takagi T-K3
Takagi T-K3-OS
Takagi T-M1


Electric Tankless Water Heaters
Stiebel Eltron
PowerStar
PowerStream


Electric Mini-Tank Water Heater
Ariston
Stiebel Eltron SHC4


Oil Tankless Water Heaters
Toyotomi


RV and Boat Water Heaters
RV 500
Boat ShowerMate


Accessories
4" Z Flex Venting
3" Z Flex Venting
AQ1 Power-vent
FXHood
Webstones Valves
Water Connections



PDF Manuals

What Size?

Site Map



Electric Tankless Water Heaters save space and save energy.
Takagi T-K JR Technical Specifications

Return to T-K Jr Water Heater Main Page



  • Technical Specs of the T-K Junior Tankless Water Heater
Power Input Natural Gas — 19,500-140,000 BTU
Propane Gas — 17,000-140,000 BTU
Water Pressure Minimum — 15 PSI
Maximum — 150 PSI
Gas Connection 3/4"Male NPT
Water Connection 3/4"Male NPT
Natural Gas Pressure Inlet Minimum — 5" WC
Maximum — 10.5" WC
LP Gas Pressure Minimum —11" WC
Maximum — 14" WC
Electrical Supply 120 Volts / 0.8 Amps
Weight 30 lbs.
Dimensions
(H x W x D)
20 inches by 14 inches by 6 inches
Minimum Flow to Activate .75 GPM
Flow Rates
(50 degree Input Water Assumed)
90°F rise / 2.4 gallons per minute
80°F rise / 2.8 gallons per minute
70°F rise / 3.1 gallons per minute
60°F rise / 3.7 gallons per minute
55°F rise / 4.1 gallons per minute
50°F rise / 4.5 gallons per minute
Manifold Pressure Natural 2.8"WC
Propane 3.2"WC
Exhaust Vent Size 4" - Sealed Stainless Steel Piping
Ignition Electronic Ignition


  • Required clearances for OUTDOOR INSTALLATION
Takagi T-K JR OUTDOOR INSTALLATION
TOP 36"
FRONT 24" (maintenance space)
BACK 1"
PIPING SIDE (bottom) 12"
SIDES 6"


  • Required clearances for INDOOR INSTALLATION
Takagi T-KJR INDOOR INSTALLATION
TOP 12"
FRONT min. 24" (maintenance space)
BACK 1"
PIPING SIDE (bottom) min. 6"
SIDES 2"


  • TK JR. Combustion Air Supply Requirements
Air Supply From Outside Building When combustion air is supplied from outside the building, an opening communicating directly with the outside should have a minimum free area of one square inch per 15,000 BTUH input of the total input rating of water heater in the enclosed area.
Air Supply From Inside Building When combustion air is supplied from inside the building, an opening communicating with the rest of the dwelling should have a minimum free area of one square inch per 1000 BTUH input of the total input rating of water heater in the enclosed area. These openings should never be less than 100 sq. in.



  • Output Temperature Ratings of the Takagi T-K JR
The T-K JR Takagi On Demand Hot Water Heater is factory preset at 122°. You can change the output temperature with the internal dipswitches to 113°, 122°, 140° or 182°. If you want to use any other temperatures than this you can purchase the optional Temperature Remote Controller (TK-RE02) that will allow the T-K JR to have output temperatures from 99° to 167°.

Please Note: Hot Water Heater Temperatures over 125°F can cause severe burns instantly or death from scalding. Children, disabled and elderly are at the highest risk of being scalded. Feel water temperature before bathing or showering.