Type:
|
Gas instantaneous, direct vent water heater designed for recreational vehicle and
mobile home use. Full gas modulation temperature control.
|
|
Dimensions:
|
Flush: 18.5" Wide x 18.25" High with rounded corners
Surface: 13.75" Wide x 13.5" Deep x 14.375" High
Weight: 27.5 pounds.
|
|
Rough-in dimensions:
|
Add 1/4" to above dimensions. For retrofit, see special directions.
|
|
Clearances:
|
Zero clearance top, bottom and sides. 2" in back for hook-ups
|
|
Construction:
|
Modular, three assemblies; gas, electronics and water.
|
|
Burner:
|
High primary air, 12 element, atmospheric type. Aluminized steel body with stainless flame strips
|
|
Heat exchanger:
|
Copper fin tube type with wrap for cooling.
|
|
Electronics:
|
Plug in, works-in-a-drawer.
|
|
Case and flue assembly:
|
Galvanized with painted aluminum access door (polar white or colonial white; surface or flush mount).
|
|
Mounting:
|
One inch mounting flanges with corner pieces and door jamb included. Must be mounted in accordance with local codes or in absence of local codes, Manufactured Home Standard, Title 24 CFR, Part 3280 or Recreational Vehicle Standard, ANSI A 119.2/NFPA501C
|
|
Hook-ups:
|
Electric: 18-2 x 2' lead.
|
|
Gas:
|
Brass 3/8" flare inside case rear or side accessible.
|
|
Water:
|
1/2" OD copper tubing. Brass compression to 1/2" NPT elbow can be installed or as specified.
|
|
Fuel:
|
Propane at 11 WCI
|
|
Capacity:
|
53,000 Btu input - 42,500 Btu output at maximum burn at 8.5 WCI manifold
pressure.15,000 Btu input - 9,600 Btu output at low burn at 1.2 WCI manifold
pressure.
(85°F temperature rise per gallon per minute continuous flow at high
burn).
|
|
Fuel consumption:
|
2.55 lbs per hour at maximum input. ( At 2 GPM of water, 20 lbs of propane will
produce over 940 gallons of hot water).
|
|
Power:
|
12 VDC at 1 amp. Operating range is 9 to 15 VDC.
|
|
Flue gas temperatures:
|
Under 300°F.
|
|
Water temperature:
|
Factory set at 115° F. Can be field adjusted 90° to 135°F.
|
|
Leakproofing:
|
Case is sealed from interior of coach. Bottom is sloped to channel water out of unit.
Hook-up plumbing is gasketed.
|
|
Gas train:
|
Burner is a 12 element high primary air, atmospheric type with stainless
steel flame strips. Aluminum manifold with brass pressure tap. Orifices,
brass # 71 x 12.
|
|
Modulating valve:
|
Solid brass conduit with 3/8" NPT ends. Control is non-intrusive into gas cavity
using no seals, pushrods or diaphragms. There is a 5:1 gas flow ratio con-trolled
by a magnetic field actuating movement of a poppet in and out of a fixed orifice.
|
|
Gas Valve:
|
Redundant solenoid with integral two stage regulator and 1/8" NPT pressure tap.
|
|
Heat exchanger:
|
Solid copper, fin tube type, 6 fins per inch with copper combustion
chamber with 1/2 " tube wrap to cool assembly.
|
|
Water Hook-ups:
|
1/2" OD copper tubes.
|
|
Water Flow meter:
|
Plastic rotary type with encapsulated magnetic rotor and Hall plate.
Clear plastic observation port.
|
|
Water Pressure relief valve:
|
Approved, set @ 100PSI.
|
|
Misc Water:
|
All other hardware in contact with water is brass or NSF approved composites.
|
|
Controls:
|
Microprocessor, controlling ignition, flame proofing, safety systems and electronic
gas modulation temperature control. Control boards are mounted in a removable drawer,
coated, with plug-in connectors protected with an anti-oxidant compound.
|
|
Ignition:
|
Direct spark type with two 2.5 second ignition attempts.
|
|
Flame proofing:
|
Rectification, shutting gas valve off in .8 of a second if proofing fails.
Ignition and proofing is effected by a single stainless probe at the burner.
|
|
Temperature sensors:
|
Three thermistors, one senses incoming water temperature
(mounted on cold water line of heat exchanger), one senses
temperature midway through heat exchanger (mounted in stainless
probe with compression fitting on the heat exchanger), and one
senses outlet temperature, (mounted to hot water outlet on the heat exchanger).
|
|
Flow meter:
|
Senses rate of water flow, (mounted on inlet water pipe).
|
|
Temperature control:
|
Maintained by microprocessor controlled gas modulation that de-livers output water
temperature within ±2°F by sensing water flow rate and three temperature
inputs.
|
|
Safety Features:
|
The Model RV 500 is pilotless. There is no flame unless water flow is sensed.
Flame rectification: Gas valve shuts off in .8 of a second if there is a flame outage.
Redundant gas solenoid.
Electronic high temperature shut-off (two).
ECO high temperature shut off @ 165°F with manual reset.
Pressure relief valve at 100 PSI.
Direct vent with combustion chamber sealed from inside of coach.
|
|
Model RV-500 Operation:
|
When unit is powered, the microprocessor activates the gas modulation valve and
per-forms component diagnostics. A green LED will flash for normal operation, red
will indicate a malfunction, signified by different codes. The unit will remain
dormant until the rotary flow meter senses at least .4 GPM of water flow. The gas
modulating valve will be set to its ignition value, the spark will be effected and
the gas valve will open. Ignition will occur and the flame will be proofed.
The microprocessor now reads water flow rate, and incoming water
temperature, calculates the required gas flow to maintain set temperature
and sets the gas modulation valve to the proper setting. The water temperature
is then monitored by the thermistors midway and at the outlet to make any minor
corrections in gas flow. If there is any change in water flow or incoming water
temperature, the microprocessor recalculates and makes any required adjustments.
The unit continues to produce hot water until water flow is stopped and
the burner turns off.
|
|
Approvals: Approved to test standard: ANSI Z21.10.3 1993
|